+/-0.1 m/s basic or <5% of reading, whichever is greater
Long Term Drift
< 1% per year
Stack/Duct Diameter
1 - 10 m standard (consult factory for other ranges)
Light Source
670nm red LED, 5 degree divergence
Optics
Quartz
Calibration
Automatic 2-point calibration once per day
Diagnostics
Continuous monitoring of sensor status including power supply voltage check, performance check, optics contamination, etc.
Ambient Temperature
-40 to 60 C
Temperature/Pressure
No effect
Moisture
0-99%
Transparency
Up to 95% opacity
Output
RS-232 ASCII, fixed data string, 4-20ma output or Fiber Optic Output
Operation
Remote display with user-selectable key pad
Copyright 2009 Optical Scientific,
Inc. All rights reserved. HIP, LEDWI, LOA, OFS, OFS-F, ORG, OWI, VIS, and WIVIS