0.1 to 1 Km with Cn2 in range of 10-16 to 10-10 m-2/3
•
Update Rate
1-minute block average
•
Diagnostics
Built-in self-test, updated once per minute, to monitor received signal strength from upper and lower channels (40 dB), turbulence, power supply condition, and micro processor status.
•
Maintenance Frequency
Every 6 months calibration check and optics cleaning
Electrical
•
Signal Output
Serial, RS-232, ASCII
•
Mains Voltage
110 VAC 50/60 Hz standard, other voltages available
Environmental
•
Temperature
-18 to 60 C
•
Humidity
0-100%, non-condensing
•
Rain/Dust
NEMA-4 type protection
Physical
•
TX Head
8.25 x 7.75 x 22 inch (210 x 195 x 560 mm)-H x W x D, 8lbs (8kg)
•
RX Head
14 x 8.25 x 22 inch (355 x 210 x 560 mm)-H x W x D, 30 lbs (14kg)
•
Enclosure
20 x 16 x 11.5 inch (510 x 405 x 290 mm)-H x W x D, 26 lbs (12kg)